Defective afci breaker

AFCI protection is sooo important.We often recommend GFI protection and forget to recommend AFCI's. Testing one inside a sub panel recently it did not trip as required leaving the bedroom circuit unprotected. If you have one in your panel you should check it per manufacturers recommendations, typically once per month. An  arc-fault circuit interrupter  ( AFCI ) also known as an  arc-fault detection device  ( AFDD ) [1]  is a  circuit breaker  that breaks the circuit when it detects an  electric arc  in the circuit it protects to prevent electrical fires. An AFCI selectively distinguishes between a harmless arc (incidental to normal operation of switches, plugs, and brushed motors), and a potentially dangerous arc (that can occur, for example, in a lamp cord which has a broken conductor). AFCI breakers have been required for circuits in residential bedrooms by since 1999

Thermal bridging

Image
Now that we use infrared cameras with some frequency, it's amazing to see things almost like a TSA agent might. The following view was taken in a living room looking up toward the ceiling/attic area Instead of seeing a skeleton of sorts when someone walks through the security camera, we can see framing behind the drywall. We are actually seeing a temperature difference, and in this case it's "Thermal Bridging" Thermal Bridging  is the movement of heat across an object that is more conductive than the materials around it. The conductive material creates a path of least resistance for heat.  Thermal bridging  can be a major source of energy loss in homes and buildings, leading to higher utility bills

Missing flashing results in thousands $$$$$$$$

Image
This home I inspected was missing some "End Dam" flashing details. Less than $100. worth of material will leave this home owner paying thousands of dollars in repairs. Make sure you get your home inspected

Outdated smoke detectors & some different types

Image
In the recent past months I have found a very  high percentage of smoke and carbon monoxide detectors are outdated. A majority of detectors require replacement every 10 years or if they "chirp" even after replacing the battery. Our state home inspection standards require us to: "Check the presence or absence of smoke alarms and carbon monoxide alarms" So, we are not required to test these devices, though it's very rare that we do not. I came across this article recently and felt it worth sharing. In short, the article is stating several states now require combination units to be installed in new homes, which I think is a huge step in the right direction. The full article is in the Columbus Dispatch http://www.dispatch.com/content/stories/home_and_garden/2016/03/27/01-state-code-embraces-photoelectric-smoke-alarms.html Prices on these units are typically less than $25. each. Certainly not worth waiting until it's too late

You should be concerned about this chimney

Image
This chimney looked questionable as we were standing on the ground. The closer we got the worst it looked. It's past time to rebuild this chimney. The buyers are considering options such as rebuilding or perhaps removing it entirely or making it cosmetic only

Deck failure?!

Image
I don't know how many times I have climbed up onto a/c platforms to gather information, check siding, electrical panels, etc. Today was not a good day for Hunt Henning to be doing so. The platform was improperly secured with approximately 14 twelve penny nails instead of using lag bolts

Water under a home

Image
This home inspection I did the other day had water front property. It literally had water running under the house both currently and lots of it in the past Lot of reasons for it not to be there. Undermining the foundation, inviting termites, mold, elevated moisture levels etc. There was so much humidity that the insulation underneath the home would stay up and the wood flooring inside was warped. The property had a brook running beside it when it rains and a high water table in the area. This will take a creative and knowledgeable contractor to keep water out and add enough ventilation to prevent mold concerns again later.

Brick Veneer Cracks

Image
It’s not uncommon to find cracks in a brick veneer sided home. Lots of different reasons are possible. Most often in our area, it’s minor settling of the slab and or foundation. An inspector would have to look at the entire homes surroundings to help determine the cause and perhaps any correction needed. In this case, the cracks are from the slab footing cracking due to water being directed toward the home. Water sitting next to a foundation is never a good idea.

Are fogged windows a cosmetic issue?

Image
By now you have probably seen a fogged window or two. There are some that can be repaired, however it will not have the insulating gas between the panes of glass as it did originally. The only way to do this is to replace the window assembly.  A typical double pane window here in the south, will have an R value of somewhere between 2.0 & 3.0. After it looses it's seal this diminishes even more. To put this R value in perspective, insulation in your attic built locally here today would be an R38! Huge difference. So, window manufactures also take into account U values which is how well or poorly it transfers heat. R-value, U-value or U-factor – R-value indicates the resistance to heat flow through a window. U-value, the inverse of R-value, indicates a window’s tendency to transfer heat. Both R-value and U-value are measures of heat flow through a window. This is a sample of how a new window might look.